Fire resistance partitions

Attic lining

Fire resistance class EI/REI 60

To calculate material consumption and costs select a correct system and go to the SYSTEM DATASHEET.


Vertical section - attic lining System name Fire resistance class EI/REI Structure Plasterboard type Plasterboard thickness Structure thickness Structure weight without wool
ZP - Attic lining
1x12,5 - plasterboard thickness [mm]
GKB A - plasterboard type
CD 60 - profile type
ES - hanger type
(W) - optionally mineral wool filling
profiles hangers
[min.] [mm] [mm] [kg/m2]


Attic lining on CD 60 profiles and ES/ES Plus hanger structure with double-layer of plasterboards
ZP - 2x15 GKF DF/CD 60, ES, W REI 60 CD 60 ES/ES Plus GKF DF 2 x 15 60 - 155 29
ZP - 2x15 GKFI DFH2/CD 60, ES, W REI 60 CD 60 ES/ES Plus GKFI DFH2 2 x 15 60 - 155 29


Attic lining on CD 60 profiles and flat hanger structure with double-layer of plasterboards
ZP - 2x15 GKF DF/CD 60, L, W REI 60 CD 60 flat GKF DF 2 x 15 60 - 230 29
ZP - 2x15 GKFI DFH2/CD 60, L, W REI 60 CD 60 flat GKFI DFH2 2 x 15 60 - 230 29


Attic lining on hat profiles structure with double-layer of plasterboards
ZP - 2x15 GKF DF/KAP, W REI 60 hat profile - GKF DF 2 x 15 45 28
ZP - 2x15 GKFI DFH2/KAP, W REI 60 hat profile - GKFI DFH2 2 x 15 45 28