Horizontal section - partition wall System name Structure Plasterboard type Plasterboard thickness Partition thickness Wall weight without wool Fire resistance class Sound insulation Maximum height 1)
SD - partition wall
SDI - installation partition wall
SDK - curved partition wall
1x12,5 - plasterboard thickness [mm]
GKB A - plasterboard type
CW 50 - profile width [mm]
W - mineral wool filling
profiles EI/REI wool thickness RW RA1 wool thickness
[mm] [mm] [kg/m2] [min.] [mm] [dB] [dB] [mm] [m]


Partition wall on CW 50 and UW 50 profiles structure with single-layer of plasterboards
SD - 1x12,5 GKB A/CW 50 CW 50 GKB A 12,5 75 17 EI 15 - - - - 3,3
SD - 1x12,5 GKBI H2/CW 50 CW 50 GKBI H2 12,5 75 18 EI 15 - - - - 3,3
SD - 1x12,5 GKF DF/CW 50 CW 50 GKF DF 12,5 75 23 EI 30 - - - - 3,3
SD - 1x12,5 GKFI DFH2/CW 50 CW 50 GKFI DFH2 12,5 75 23 EI 30 - - - - 3,3
SD - 1x12,5 DFH2IR/CW 50 CW 50 DFH2IR 12,5 75 25 EI 30 - - - - 3,3
SD - 1x15 GKF DF/CW 50 CW 50 GKF DF 15 80 28 EI 60 - - - - 3,3
SD - 1x15 GKFI DFH2/CW 50 CW 50 GKFI DFH2 15 80 28 EI 60 - - - - 3,3


Partition wall on CW 75 and UW 75 profiles structure with single-layer of plasterboards
SD - 1x12,5 GKB A/CW 75 CW 75 GKB A 12,5 100 17 EI 15 - - - - 4,4
SD - 1x12,5 GKBI H2/CW 75 CW 75 GKBI H2 12,5 100 18 EI 15 - - - - 4,4
SD - 1x12,5 GKF DF/CW 75 CW 75 GKF DF 12,5 100 23 EI 45 - - - - 4,4
SD - 1x12,5 GKFI DFH2/CW 75 CW 75 GKFI DFH2 12,5 100 23 EI 45 - - - - 4,4
SD - 1x12,5 DFH2IR/CW 75 CW 75 DFH2IR 12,5 100 25 EI 45 - - - - 4,4
SD - 1x15 GKF DF/CW 75 CW 75 GKF DF 15 105 28 EI 60 - - - - 4,4
SD - 1x15 GKFI DFH2/CW 75 CW 75 GKFI DFH2 15 105 28 EI 60 - - - - 4,4


Partition wall on CW 100 and UW 100 profiles structure with single-layer of plasterboards
SD - 1x12,5 GKB A/CW 100 CW 100 GKB A 12,5 125 18 EI 15 - - - - 5,8
SD - 1x12,5 GKBI H2/CW 100 CW 100 GKBI H2 12,5 125 19 EI 15 - - - - 5,8
SD - 1x12,5 GKF DF/CW 100 CW 100 GKF DF 12,5 125 24 EI 45 - - - - 5,8
SD - 1x12,5 GKFI DFH2/CW 100 CW 100 GKFI DFH2 12,5 125 24 EI 45 - - - - 5,8
SD - 1x12,5 DFH2IR/CW 100 CW 100 DFH2IR 12,5 125 26 EI 45 - - - - 5,8
SD - 1x15 GKF DF/CW 100 CW 100 GKF DF 15 130 29 EI 60 - - - - 5,8
SD - 1x15 GKFI DFH2/CW 100 CW 100 GKFI DFH2 15 130 29 EI 60 - - - - 5,8


Partition wall on CW 50 and UW 50 profiles structure with single-layer of plasterboards with mineral wool filling
SD - 1x12,5 GKB A/CW 50 W CW 50 GKB A 12,5 75 17 EI 15 - 38 33 50 3,3
SD - 1x12,5 GKBI H2/CW 50 W CW 50 GKBI H2 12,5 75 18 EI 15 - 38 33 50 3,3
SD - 1x12,5 GKF DF/CW 50 W CW 50 GKF DF 12,5 75 23 EI 60 50 43 38 50 3,3
SD - 1x12,5 GKFI DFH2/CW 50 W CW 50 GKFI DFH2 12,5 75 23 EI 60 50 43 38 50 3,3
SD - 1x12,5 DFH2IR/CW 50 W CW 50 DFH2IR 12,5 75 25 EI 60 50 46 41 50 3,3
SD - 1x15 GKF DF/CW 50 W CW 50 GKF DF 15 80 28 EI 60 - - - - 3,3
SD - 1x15 GKFI DFH2/CW 50 W CW 50 GKFI DFH2 15 80 28 EI 60 - - - - 3,3


Partition wall on CW 75 and UW 75 profiles structure with single-layer of plasterboards with mineral wool filling
SD - 1x12,5 GKB A/CW 75 W CW 75 GKB A 12,5 100 17 EI 15 - 42 36 75 4,4
SD - 1x12,5 GKBI H2/CW 75 W CW 75 GKBI H2 12,5 100 18 EI 15 - 42 36 75 4,4
SD - 1x12,5 GKF DF/CW 75 W CW 75 GKF DF 12,5 100 23 EI 60 50 47 42 70 4,4
SD - 1x12,5 GKFI DFH2/CW 75 W CW 75 GKFI DFH2 12,5 100 23 EI 60 50 47 42 70 4,4
SD - 1x12,5 DFH2IR/CW 75 W CW 75 DFH2IR 12,5 100 25 EI 60 50 49 45 75 4,4
SD - 1x15 GKF DF/CW 75 W CW 75 GKF DF 15 105 28 EI 60 - - - - 4,4
SD - 1x15 GKFI DFH2/CW 75 W CW 75 GKFI DFH2 15 105 28 EI 60 - - - - 4,4


Partition wall on CW 100 and UW 100 profiles structure with single-layer of plasterboards with mineral wool filling
SD - 1x12,5 GKB A/CW 100 W CW 100 GKB A 12,5 125 18 EI 15 - 45 39 100 5,8
SD - 1x12,5 GKBI H2/CW 100 W CW 100 GKBI H2 12,5 125 19 EI 15 - 45 39 100 5,8
SD - 1x12,5 GKF DF/CW 100 W CW 100 GKF DF 12,5 125 24 EI 90 100 47 45 100 5,8
SD - 1x12,5 GKFI DFH2/CW 100 W CW 100 GKFI DFH2 12,5 125 24 EI 90 100 47 45 100 5,8
SD - 1x12,5 DFH2IR/CW 100 W CW 100 DFH2IR 12,5 125 26 EI 90 100 52 49 100 5,8
SD - 1x15 GKF DF/CW 100 W CW 100 GKF DF 15 130 29 EI 90 100 - - - 5,8
SD - 1x15 GKFI DFH2/CW 100 W CW 100 GKFI DFH2 15 130 29 EI 90 100 - - - 5,8


Partition wall on CW 50 and UW 50 profiles structure with double-layer of plasterboards
SD - 2x12,5 GKB A/CW 50 CW 50 GKB A 2 x 12,5 100 32 EI 60 - - - - 4,2
SD - 2x12,5 GKBI H2/CW 50 CW 50 GKBI H2 2 x 12,5 100 34 EI 60 - - - - 4,2
SD - 2x12,5 GKF DF/CW 50 CW 50 GKF DF 2 x 12,5 100 44 EI 120 - - - - 4,2
SD - 2x12,5 GKFI DFH2/CW 50 CW 50 GKFI DFH2 2 x 12,5 100 44 EI 120 - - - - 4,2
SD - 2x12,5 DFH2IR/CW 50 CW 50 DFH2IR 2 x 12,5 100 48 EI 120 - - - - 4,2
SD - 2x15 GKF DF/CW 50 CW 50 GKF DF 2 x 15 110 54 EI 120 - - - - 4,2
SD - 2x15 GKFI DFH2/CW 50 CW 50 GKFI DFH2 2 x 15 110 54 EI 120 - - - - 4,2


Partition wall on CW 75 and UW 75 profiles structure with double-layer of plasterboards
SD - 2x12,5 GKB A/CW 75 CW 75 GKB A 2 x 12,5 125 32 EI 60 - - - - 5,8
SD - 2x12,5 GKBI H2/CW 75 CW 75 GKBI H2 2 x 12,5 125 34 EI 60 - - - - 5,8
SD - 2x12,5 GKF DF/CW 75 CW 75 GKF DF 2 x 12,5 125 44 EI 120 - - - - 5,8
SD - 2x12,5 GKFI DFH2/CW 75 CW 75 GKFI DFH2 2 x 12,5 125 44 EI 120 - - - - 5,8
SD - 2x12,5 DFH2IR/CW 75 CW 75 DFH2IR 2 x 12,5 125 48 EI 120 - - - - 5,8
SD - 2x15 GKF DF/CW 75 CW 75 GKF DF 2 x 15 135 54 EI 120 - - - - 5,8
SD - 2x15 GKFI DFH2/CW 75 CW 75 GKFI DFH2 2 x 15 135 54 EI 120 - - - - 5,8


Partition wall on CW 100 and UW 100 profiles structure with double-layer of plasterboards
SD - 2x12,5 GKB A/CW 100 CW 100 GKB A 2 x 12,5 150 33 EI 60 - - - - 6,5
SD - 2x12,5 GKBI H2/CW 100 CW 100 GKBI H2 2 x 12,5 150 35 EI 60 - - - - 6,5
SD - 2x12,5 GKF DF/CW 100 CW 100 GKF DF 2 x 12,5 150 45 EI 120 - - - - 6,5
SD - 2x12,5 GKFI DFH2/CW 100 CW 100 GKFI DFH2 2 x 12,5 150 45 EI 120 - - - - 6,5
SD - 2x12,5 DFH2IR/CW 100 CW 100 DFH2IR 2 x 12,5 150 49 EI 120 - - - - 6,5
SD - 2x15 GKF DF/CW 100 CW 100 GKF DF 2 x 15 160 55 EI 120 - - - - 6,5
SD - 2x15 GKFI DFH2/CW 100 CW 100 GKFI DFH2 2 x 15 160 55 EI 120 - - - - 6,5


Partition wall on CW 50 and UW 50 profiles structure with double-layer of plasterboards with mineral wool filling
SD - 2x12,5 GKB A/CW 50 W CW 50 GKB A 2 x 12,5 100 32 EI 90 50 49 42 50 4,2
SD - 2x12,5 GKBI H2/CW 50 W CW 50 GKBI H2 2 x 12,5 100 34 EI 90 50 49 42 50 4,2
SD - 2x12,5 GKF DF/CW 50 W CW 50 GKF DF 2 x 12,5 100 44 EI 120 - 52 48 50 4,2
SD - 2x12,5 GKFI DFH2/CW 50 W CW 50 GKFI DFH2 2 x 12,5 100 44 EI 120 - 52 48 50 4,2
SD - 2x12,5 DFH2IR/CW 50 W CW 50 DFH2IR 2 x 12,5 100 48 EI 120 - 53 50 50 4,2
SD - 2x15 GKF DF/CW 50 W CW 50 GKF DF 2 x 15 110 54 EI 120 - - - - 4,2
SD - 2x15 GKFI DFH2/CW 50 W CW 50 GKFI DFH2 2 x 15 110 54 EI 120 - - - - 4,2


Partition wall on CW 75 and UW 75 profiles structure with double-layer of plasterboards with mineral wool filling
SD - 2x12,5 GKB A/CW 75 W CW 75 GKB A 2 x 12,5 125 32 EI 90 50 51 47 75 5,8
SD - 2x12,5 GKBI H2/CW 75 W CW 75 GKBI H2 2 x 12,5 125 34 EI 90 50 51 47 75 5,8
SD - 2x12,5 GKF DF/CW 75 W CW 75 GKF DF 2 x 12,5 125 44 EI 120 - 56 53 75 5,8
SD - 2x12,5 GKFI DFH2/CW 75 W CW 75 GKFI DFH2 2 x 12,5 125 44 EI 120 - 56 53 75 5,8
SD - 2x12,5 DFH2IR/CW 75 W CW 75 DFH2IR 2 x 12,5 125 48 EI 120 - 57 54 75 5,8
SD - 2x15 GKF DF/CW 75 W CW 75 GKF DF 2 x 15 135 54 EI 120 - - - - 5,8
SD - 2x15 GKFI DFH2/CW 75 W CW 75 GKFI DFH2 2 x 15 135 54 EI 120 - - - - 5,8


Partition wall on CW 100 and UW 100 profiles structure with double-layer of plasterboards with mineral wool filling
SD - 2x12,5 GKB A/CW 100 W CW 100 GKB A 2 x 12,5 150 33 EI 90 50 52 50 100 6,5
SD - 2x12,5 GKBI H2/CW 100 W CW 100 GKBI H2 2 x 12,5 150 35 EI 90 50 52 50 100 6,5
SD - 2x12,5 GKF DF/CW 100 W CW 100 GKF DF 2 x 12,5 150 45 EI 120 - 55 53 100 6,5
SD - 2x12,5 GKFI DFH2/CW 100 W CW 100 GKFI DFH2 2 x 12,5 150 45 EI 120 - 55 53 100 6,5
SD - 2x12,5 DFH2IR/CW 100 W CW 100 DFH2IR 2 x 12,5 150 49 EI 120 - 58 57 100 6,5
SD - 2x15 GKF DF/CW 100 W CW 100 GKF DF 2 x 15 160 55 EI 120 - - - - 6,5
SD - 2x15 GKFI DFH2/CW 100 W CW 100 GKFI DFH2 2 x 15 160 55 EI 120 - - - - 6,5


Partition wall on CW 50 and UW 50 profiles structure with triple-layer of plasterboards
SD - 3x12,5 GKF DF/CW 50 CW 50 GKF DF 3 x 12,5 125 65 EI 180 - - - - 4,4
SD - 3x12,5 GKFI DFH2/CW 50 CW 50 GKFI DFH2 3 x 12,5 125 65 EI 180 - - - - 4,4
SD - 3x12,5 DFH2IR/CW 50 CW 50 DFH2IR 3 x 12,5 125 71 EI 180 - - - - 4,4
SD - 3x15 GKF DF/CW 50 CW 50 GKF DF 3 x 15 140 80 EI 180 - - - - 4,4
SD - 3x15 GKFI DFH2/CW 50 CW 50 GKFI DFH2 3 x 15 140 80 EI 180 - - - - 4,4


Partition wall on CW 75 and UW 75 profiles structure with triple-layer of plasterboards
SD - 3x12,5 GKF DF/CW 75 CW 75 GKF DF 3 x 12,5 150 65 EI 180 - - - - 6,4
SD - 3x12,5 GKFI DFH2/CW 75 CW 75 GKFI DFH2 3 x 12,5 150 65 EI 180 - - - - 6,4
SD - 3x12,5 DFH2IR/CW 75 CW 75 DFH2IR 3 x 12,5 150 71 EI 180 - - - - 6,4
SD - 3x15 GKF DF/CW 75 CW 75 GKF DF 3 x 15 165 80 EI 180 - - - - 6,4
SD - 3x15 GKFI DFH2/CW 75 CW 75 GKFI DFH2 3 x 15 165 80 EI 180 - - - - 6,4


Partition wall on CW 100 and UW 100 profiles structure with triple-layer of plasterboards
SD - 3x12,5 GKF DF/CW 100 CW 100 GKF DF 3 x 12,5 175 66 EI 180 - - - - 6,6
SD - 3x12,5 GKFI DFH2/CW 100 CW 100 GKFI DFH2 3 x 12,5 175 66 EI 180 - - - - 6,6
SD - 3x12,5 DFH2IR/CW 100 CW 100 DFH2IR 3 x 12,5 175 72 EI 180 - - - - 6,6
SD - 3x15 GKF DF/CW 100 CW 100 GKF DF 3 x 15 190 81 EI 180 - - - - 6,6
SD - 3x15 GKFI DFH2/CW 100 CW 100 GKFI DFH2 3 x 15 190 81 EI 180 - - - - 6,6


Partition wall on CW 50 and UW 50 profiles structure with triple-layer of plasterboards with mineral wool filling
SD - 3x12,5 GKB A/CW 50 W CW 50 GKB A 3 x 12,5 125 47 - - - - - 4,4
SD - 3x12,5 GKBI H2/CW 50 W CW 50 GKBI H2 3 x 12,5 125 50 - - - - - 4,4
SD - 3x12,5 GKF DF/CW 50 W CW 50 GKF DF 3 x 12,5 125 65 EI 180 - - - - 4,4
SD - 3x12,5 GKFI DFH2/CW 50 W CW 50 GKFI DFH2 3 x 12,5 125 65 EI 180 - - - - 4,4
SD - 3x12,5 DFH2IR/CW 50 W CW 50 DFH2IR 3 x 12,5 125 71 EI 180 - - - - 4,4
SD - 3x15 GKF DF/CW 50 W CW 50 GKF DF 3 x 15 140 80 EI 180 - - - - 4,4
SD - 3x15 GKFI DFH2/CW 50 W CW 50 GKFI DFH2 3 x 15 140 80 EI 180 - - - - 4,4


Partition wall on CW 75 and UW 75 profiles structure with triple-layer of plasterboards with mineral wool filling
SD - 3x12,5 GKB A/CW 75 W CW 75 GKB A 3 x 12,5 150 47 - - - - - 6,4
SD - 3x12,5 GKBI H2/CW 75 W CW 75 GKBI H2 3 x 12,5 150 50 - - - - - 6,4
SD - 3x12,5 GKF DF/CW 75 W CW 75 GKF DF 3 x 12,5 150 65 EI 180 - - - - 6,4
SD - 3x12,5 GKFI DFH2/CW 75 W CW 75 GKFI DFH2 3 x 12,5 150 65 EI 180 - - - - 6,4
SD - 3x12,5 DFH2IR/CW 75 W CW 75 DFH2IR 3 x 12,5 150 71 EI 180 - - - - 6,4
SD - 3x15 GKF DF/CW 75 W CW 75 GKF DF 3 x 15 165 80 EI 180 - - - - 6,4
SD - 3x15 GKFI DFH2/CW 75 W CW 75 GKFI DFH2 3 x 15 165 80 EI 180 - - - - 6,4


Partition wall on CW 100 and UW 100 profiles structure with triple-layer of plasterboards with mineral wool filling
SD - 3x12,5 GKB A/CW 100 W CW 100 GKB A 3 x 12,5 175 48 - - - - - 6,6
SD - 3x12,5 GKBI H2/CW 100 W CW 100 GKBI H2 3 x 12,5 175 51 - - - - - 6,6
SD - 3x12,5 GKF DF/CW 100 W CW 100 GKF DF 3 x 12,5 175 66 EI 180 - - - - 6,6
SD - 3x12,5 GKFI DFH2/CW 100 W CW 100 GKFI DFH2 3 x 12,5 175 66 EI 180 - - - - 6,6
SD - 3x12,5 DFH2IR/CW 100 W CW 100 DFH2IR 3 x 12,5 175 72 EI 180 - - - - 6,6
SD - 3x15 GKF DF/CW 100 W CW 100 GKF DF 3 x 15 190 81 EI 180 - - - - 6,6
SD - 3x15 GKFI DFH2/CW 100 W CW 100 GKFI DFH2 3 x 15 190 81 EI 180 - - - - 6,6


Partition wall on double CW 50 and UW 50 profiles structure with double-layer of plasterboards with mineral wool filling
SD - 2x12,5 GKB A/2xCW 50 2xW 2 x CW 50 GKB A 2 x 12,5 155 34 EI 90 50 60 57 2x50 4,4
SD - 2x12,5 GKBI H2/2xCW 50 2xW 2 x CW 50 GKBI H2 2 x 12,5 155 36 EI 90 50 60 57 2x50 4,4
SD - 2x12,5 GKF DF/2xCW 50 2xW 2 x CW 50 GKF DF 2 x 12,5 155 46 EI 120 - - - - 4,4
SD - 2x12,5 GKFI DFH2/2xCW 50 2xW 2 x CW 50 GKFI DFH2 2 x 12,5 155 46 EI 120 - - - - 4,4
SD - 2x12,5 DFH2IR/2xCW 50 2xW 2 x CW 50 DFH2IR 2 x 12,5 155 50 EI 120 - 63 61 2 x 50 4,4
SD - 2x15 GKF DF/2xCW 50 2xW 2 x CW 50 GKF DF 2 x 15 165 56 EI 120 - - - - 4,4
SD - 2x15 GKFI DFH2/2xCW 50 2xW 2 x CW 50 GKFI DFH2 2 x 15 165 56 EI 120 - - - - 4,4


Partition wall on double CW 75 and UW 75 profiles structure with double-layer of plasterboards with mineral wool filling
SD - 2x12,5 GKB A/2xCW 75 2xW 2 x CW 75 GKB A 2 x 12,5 205 34 EI 90 50 62 58 2x75 6,0
SD - 2x12,5 GKBI H2/2xCW 75 2xW 2 x CW 75 GKBI H2 2 x 12,5 205 36 EI 90 50 62 58 2x75 6,0
SD - 2x12,5 GKF DF/2xCW 75 2xW 2 x CW 75 GKF DF 2 x 12,5 205 46 EI 120 - - - - 6,0
SD - 2x12,5 GKFI DFH2/2xCW 75 2xW 2 x CW 75 GKFI DFH2 2 x 12,5 205 46 EI 120 - - - - 6,0
SD - 2x12,5 DFH2IR/2xCW 75 2xW 2 x CW 75 DFH2IR 2 x 12,5 205 50 EI 120 - 64 62 2 x 75 6,0
SD - 2x15 GKF DF/2xCW 75 2xW 2 x CW 75 GKF DF 2 x 15 215 56 EI 120 - - - - 6,0
SD - 2x15 GKFI DFH2/2xCW 75 2xW 2 x CW 75 GKFI DFH2 2 x 15 215 56 EI 120 - - - - 6,0


Partition wall on double CW 100 and UW 100 profiles structure with double-layer of plasterboards with mineral wool filling
SD - 2x12,5 GKB A/2xCW 100 2xW 2 x CW 100 GKB A 2 x 12,5 255 35 EI 90 50 63 60 2x100 6,8
SD - 2x12,5 GKBI H2/2xCW 100 2xW 2 x CW 100 GKBI H2 2 x 12,5 255 37 EI 90 50 63 60 2x100 6,8
SD - 2x12,5 GKF DF/2xCW 100 2xW 2 x CW 100 GKF DF 2 x 12,5 255 47 EI 120 - - - - 6,8
SD - 2x12,5 GKFI DFH2/2xCW 100 2xW 2 x CW 100 GKFI DFH2 2 x 12,5 255 47 EI 120 - - - - 6,8
SD - 2x12,5 DFH2IR/CW 100 2xW 2 x CW 100 DFH2IR 2 x 12,5 255 51 EI 120 - 66 65 2 x 100 6,8
SD - 2x15 GKF DF/CW 100 2xW 2 x CW 100 GKF DF 2 x 15 265 57 EI 120 - - - - 6,8
SD - 2x15 GKFI DFH2/CW 100 2xW 2 x CW 100 GKFI DFH2 2 x 15 265 57 EI 120 - - - - 6,8


Partition wall on double CW and UW profiles structure with triple-layer of plasterboards with mineral wool filling
SD - 3x12,5 GKF DF/2xCW 50 2xW 2 x CW 50 GKF DF 3 x 12,5 175 67 EI 180 - - - - 4,6
SD - 3x12,5 GKFI DFH2/2xCW 50 2xW 2 x CW 50 GKFI DFH2 3 x 12,5 175 67 EI 180 - - - - 4,6
SD - 3x12,5 DFH2IR/2xCW 50 2xW 2 x CW 50 DFH2IR 3 x 12,5 175 73 EI 180 - - - - 4,6
SD - 3x12,5 GKF DF/2xCW 75 2xW 2 x CW 75 GKF DF 3 x 12,5 225 67 EI 180 - - - - 6,7
SD - 3x12,5 GKFI DFH2/2xCW 75 2xW 2 x CW 75 GKFI DFH2 3 x 12,5 225 67 EI 180 - - - - 6,7
SD - 3x12,5 DFH2IR/2xCW 75 2xW 2 x CW 75 DFH2IR 3 x 12,5 225 73 EI 180 - - - - 6,7
SD - 3x12,5 GKF DF/2xCW 100 2xW 2 x CW 100 GKF DF 3 x 12,5 275 68 EI 180 - - - - 6,9
SD - 3x12,5 GKFI DFH2/2xCW 100 2xW 2 x CW 100 GKFI DFH2 3 x 12,5 275 68 EI 180 - - - - 6,9
SD - 3x12,5 DFH2IR/2xCW 100 2xW 2 x CW 100 DFH2IR 3 x 12,5 275 74 EI 180 - - - - 6,9


Installation partition wall on double CW 50 and UW 50 profiles structure with double-layer of plasterboards with mineral wool filling
SDI - 2x12,5 GKB A/2xCW 50 W 2 x CW 50 GKB A 2 x 12,5 up to 280 35 EI 90 50 55 52 50 4,9
SDI - 2x12,5 GKBI H2/2xCW 50 W 2 x CW 50 GKBI H2 2 x 12,5 up to 280 37 EI 90 50 55 52 50 4,9
SDI - 2x12,5 GKF DF/2xCW 50 W 2 x CW 50 GKF DF 2 x 12,5 up to 280 47 EI 120 - - - - 4,9
SDI - 2x12,5 GKFI DFH2/2xCW 50 W 2 x CW 50 GKFI DFH2 2 x 12,5 up to 280 47 EI 120 - - - - 4,9
SDI - 2x12,5 DFH2IR/2xCW 50 W 2 x CW 50 DFH2IR 2 x 12,5 up to 280 51 EI 120 - 56 54 50 4,9
SDI - 2x15 GKF DF/2xCW 50 W 2 x CW 50 GKF DF 2 x 15 up to 280 57 EI 120 - - - - 4,9
SDI - 2x15 GKFI DFH2/2xCW 50 W 2 x CW 50 GKFI DFH2 2 x 15 up to 280 57 EI 120 - - - - 4,9


Installation partition wall on double CW 75 and UW 75 profiles structure with double-layer of plasterboards with mineral wool filling
SDI - 2x12,5 GKB A/2xCW 75 W 2 x CW 75 GKB A 2 x 12,5 up to 330 35 EI 90 50 55 51 75 6,7
SDI - 2x12,5 GKBI H2/2xCW 75 W 2 x CW 75 GKBI H2 2 x 12,5 up to 330 37 EI 90 50 55 51 75 6,7
SDI - 2x12,5 GKF DF/2xCW 75 W 2 x CW 75 GKF DF 2 x 12,5 up to 330 47 EI 120 - - - - 6,7
SDI - 2x12,5 GKFI DFH2/2xCW 75 W 2 x CW 75 GKFI DFH2 2 x 12,5 up to 330 47 EI 120 - - - - 6,7
SDI - 2x12,5 DFH2IR/2xCW 75 W 2 x CW 75 DFH2IR 2 x 12,5 up to 330 51 EI 120 - 61 59 75 6,7
SDI - 2x15 GKF DF/2xCW 75 W 2 x CW 75 GKF DF 2 x 15 up to 330 57 EI 120 - - - - 6,7
SDI - 2x15 GKFI DFH2/2xCW 75 W 2 x CW 75 GKFI DFH2 2 x 15 up to 330 57 EI 120 - - - - 6,7


Installation partition wall on double CW 100 and UW 100 profiles structure with double-layer of plasterboards with mineral wool filling
SDI - 2x12,5 GKB A/2xCW 100 W 2 x CW 100 GKB A 2 x 12,5 up to 380 36 EI 90 50 55 53 100 7,5
SDI - 2x12,5 GKBI H2/2xCW 100 W 2 x CW 100 GKBI H2 2 x 12,5 up to 380 38 EI 90 50 55 53 100 7,5
SDI - 2x12,5 GKF DF/2xCW 100 W 2 x CW 100 GKF DF 2 x 12,5 up to 380 48 EI 120 - - - - 7,5
SDI - 2x12,5 GKFI DFH2/2xCW 100 W 2 x CW 100 GKFI DFH2 2 x 12,5 up to 380 48 EI 120 - - - - 7,5
SDI - 2x12,5 DFH2IR/CW 100 W 2 x CW 100 DFH2IR 2 x 12,5 up to 380 52 EI 120 - 59 57 100 7,5
SDI - 2x15 GKF DF/CW 100 W 2 x CW 100 GKF DF 2 x 15 up to 380 58 EI 120 - - - - 7,5
SDI - 2x15 GKFI DFH2/CW 100 W 2 x CW 100 GKFI DFH2 2 x 15 up to 380 58 EI 120 - - - - 7,5


Installation partition wall on double CW and UW profiles structure with triple-layer of plasterboards with mineral wool filling
SDI - 3x12,5 GKF DF/2xCW 50 W 2 x CW 50 GKF DF 3 x 12,5 up to 305 68 EI 180 - - - - 5,1
SDI - 3x12,5 GKFI DFH2/2xCW 50 W 2 x CW 50 GKFI DFH2 3 x 12,5 up to 305 68 EI 180 - - - - 5,1
SDI - 3x12,5 DFH2IR/2xCW 50 W 2 x CW 50 DFH2IR 3 x 12,5 up to 305 74 EI 180 - - - - 5,1
SDI - 3x12,5 GKF DF/2xCW 75 W 2 x CW 75 GKF DF 3 x 12,5 up to 355 68 EI 180 - - - - 7,4
SDI - 3x12,5 GKFI DFH2/2xCW 75 W 2 x CW 75 GKFI DFH2 3 x 12,5 up to 355 68 EI 180 - - - - 7,4
SDI - 3x12,5 DFH2IR/2xCW 75 W 2 x CW 75 DFH2IR 3 x 12,5 up to 355 74 EI 180 - - - - 7,4
SDI - 3x12,5 GKF DF/2xCW 100 W 2 x CW 100 GKF DF 3 x 12,5 up to 405 69 EI 180 - - - - 7,5
SDI - 3x12,5 GKFI DFH2/2xCW 100 W 2 x CW 100 GKFI DFH2 3 x 12,5 up to 405 69 EI 180 - - - - 7,5
SDI - 3x12,5 DFH2IR/2xCW 100 W 2 x CW 100 DFH2IR 3 x 12,5 up to 405 75 EI 180 - - - - 7,5


Curved partition wall on CW 50 and U 50 profiles structure with double-layer of plasterboards with mineral wool filling
SDK - 2x6,5 Norflex A/CW 50 W CW 50 Norflex A 2 x 6,5 76 25 - - - - - 4,0
SDK - 2x6,5 Norflex A/CW 75 W CW 75 Norflex A 2 x 6,5 101 26 - - - - - 4,5


1) The specified maximum wall height refers to structures made of profiles with 0,6 mm thick sheet metal and CW profiles spaced every 600 mm. This hight does not apply to walls with qualified fire resistance and refers to rooms where only a few persons are present simultaneously (e.g. rooms in flats, hotels, hospitals). See the System Datasheet for details.